Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1). They shall be passenger elevators as classified by ASME A17.1....
Search Results "ANSI/IEEE: American National Standards Institute/ Institute of Electrical and Electronics Engineers"
-
407.1 General
- Handbook of Construction Tolerances by David Kent Ballast FAIA, CSI
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
PREFACE
The first version of the Americans with Disabilities Act (ADA) that went before Congress was crafted by President Ronald Reagan’s appointees to the National Council on Disability....
-
Lutron Wallbox Maestro Lighting Controls
Requires the Premium User plan or above. (Login or upgrade your account!)
-
General: ADA Standard Section 105.1
Section 105.1 of the ADA Standards covers information on the Referenced Standards throughout the ADA Standards.
-
CASI California Survey Reports Acceptance Criteria - Equivalent Facilitation AC 01-12
Certified Access Specialist Institute | California Survey Reports | Acceptance Criteria _______________________________________________________________________________________ Equivalent...
-
11B-105 Referenced standards
[See subsections ...]
-
11B-105 Referenced standards
[See subsections ...]
-
11B-812 Electric vehicle charging stations
ETA Editor's Note EVCS are not addressed by 2010 ADA Standards, although a case could be made, based on the general obligation for governments to make their services, programs...
-
11B-812 Electric vehicle charging stations
ETA Editor's Note EVCS are not addressed by 2010 ADA Standards, although a case could be made, based on the general obligation for governments to make their services, programs...
-
Limited-Use/ Limited-Application Elevators [§408]
LULAs differ from those of §407 in that: Hoistway doors can be swinging type (they must open and close automatically, be power-operated, meet requirements for doors and referenced ANSI...
-
1. Evolving Approach to Covered Electronic Content
This growth, coupled with the fact that the existing standards do not clearly spell out the scope of covered electronic content, led to inconsistencies in accessibility of electronic data...
-
FAQ: I am a member of a professional association that provides complimentary Corada subscriptions as a benefit of membership. Can I add on colleagues, co-workers or staff to my subscription at the organization's discounted rate?
Because these organizations choose to provide Corada subscriptions as a benefit of membership, any person added to your Group subscription who is NOT a member of one of...
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be...
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum. Exception: Existing...
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically. They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door...
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
4.10.1 General
Accessible elevators shall be on an accessible route and shall comply with 4.10 and with the ASME A17.1‒1990, Safety Code for Elevators and Escalators. Freight elevators shall not be...
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be...
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum. Exception: Existing...
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum. Exception: Existing...
-
11B-411.1 General
Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1. Elevator operation shall be...