Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1220 mm) between handrails....
Search Results "Ticketing Area"
Commonly Searched Documents
-
1009.7.4 Stairways
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.
-
1008.2.5.1 Ground Level
1008.2.5.1 Ground Level. Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.
-
11. When a composite play structure provides more than 20 elevated play components and ramp access to at least 25% of the elevated play components is provided, do the elevated play components need to be of different types as well?
11. When a composite play structure provides more than 20 elevated play components and ramp access to at least 25% of the elevated play components is provided, do the elevated play...
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum.
-
T502.3.2 Thresholds
Thresholds at doorways shall be marked by a stripe. The stripe shall be 1 inch (25 mm) wide minimum and contrast with the rest of the walking surface either light-on-dark or...
-
2004 ADA Checklist for Polling Places
ADA Checklist for Polling Places February 2004 Reproduction The ADA authorizes the Department of Justice to provide technical assistance to individuals and entities...
-
4.1.6(1)(g)
(g) In alterations, the requirements of 4.1.3(9), 4.3.10 and 4.3.11 do not apply.
-
4.34.2(1)
(1) Common spaces and facilities serving individual accessible dwelling units (for example, entry walks, trash disposal facilities, and mail boxes) shall comply with 4.2 through 4.33.
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.
-
§ 38.111(a)(3)
(3) Bi-level dining cars shall comply with §§38.113(a)(2), 38.115(b), 38.117(a), and 38.121 of this part.
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.
-
1007.7.6 Stairway
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1009.10 Directional signage
Within areas of refuge....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
§382.51(b)(1)
(1) This means that passengers with a disability must be able to move readily through such terminal facilities to get to or from the gate and any other area from which passengers board the...
-
14 CFR Parts 382 and 399; 49 CFR Part 27 - Nondiscrimination on the Basis of Disability in Air Travel: Accessibility of Web Sites and Automated Kiosks at U.S. Airports - Preamble
In addition, the Department is amending its rule that prohibits unfair and deceptive practices and unfair methods of competition to require ticket agents that are not small businesses to...
-
Section 35.150(b)(4) and (5) Existing Play Areas and Recreation Facilities (Section-by-Section Analysis)
[See subsections ...]
-
1007.2 Continuity and components
1007.2 Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
Maneuvering Space at Doors
Comment. Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard. These commenters stated that...
-
1009.2 Continuity and components
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
-
§382.51(a)(2)
deplaning by level-entry loading bridges or accessible passenger lounges to and from an aircraft is not available, you must ensure that there is an accessible route between the gate and the area...