Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
Search Results "Self-Closing Door"
-
11B-407.4.1 Car dimensions
-
11B-407.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
-
2. b. WIDE AND EASY TO OPEN EXTERIOR AND INTERIOR DOORS
[See subsections ...]
- NABCO GT1400 / Automatic Standard Folding Door
-
H5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
- PC Doors Pocket Door EZ-Closer
-
4.2.5. Device Replacement
As discussed in Section 3.6.2, captioning and audio description devices will likely need to be replaced on a regular basis because they will be under heavy use from patrons. ...
-
11B-407.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1....
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
F216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory F216.4.1 Exit Doors....
-
216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory 216.4.1 Exit Doors....
- SecurityMAX™ Package and SmartTouch® Bolt by Milgard
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
Maintaining Accessibility in Museum Shops
Museum shops must not allow merchandise to spill into aisles and narrow the width of the accessible route. Sales and ticket counters that have been lowered to provide...
-
Stacks [8.5]
Stacks [8.5] Elements fixed to stacks, such as ladders, cannot reduce the minimum passage width nor should signs or other elements between 27 to 80 inches above the floor project...
-
5.3 TABLEWARE AREAS
Install tableware, dishware, condiment, food and beverage display shelves, and dispensing devices in compliance with 4.2 (see Fig. 54).
-
Factors to consider when making decisions about what is readily achievable (and not readily achievable)
Making decisions about barrier removal and whether it is readily achievable is done on a case-by-case basis. Factors to consider include: The nature and cost of the barrier...
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
- Hafele America Co. Pocket Door Hardware
-
Sec.36.303(b)(1)
computer-aided transcription services, written materials, telephone handset amplifiers, assistive listening devices, assistive listening systems, telephones compatible with hearing aids, closed...
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....