The minimum size (30” by 48”) applies whether the space is positioned for forward or side approaches....
Search Results "Push Side"
-
Surface and Size [§305.2 and §305.3]
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
5. Bed with clear floor space
Bed with clear floor space for a side approach next to bed....
-
Ramps
Provide handrails on each side of the ramps at the following locations:...
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
Parking Spaces [4.6.3]
For vans with side-mounted lifts, a combined width of almost 17 feet is often needed for the deployment and use of side-mounted lifts; ADAAG requires at least 16 feet....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
Automatic Doors and Power Assisted Doors [4.13.12]
Most operate slowly, allow manual opening, and are often activated by a push button or plate....
-
10.3.1(7)*
Gates which must be pushed open by wheelchair or mobility aid users shall have a smooth continuous surface extending from 2 inches above the floor to 27 inches above the floor and shall...
-
Operating Hardware
Lever-operated mechanisms, push-type mechanisms, and U-shaped handles are acceptable designs. ADA Standards 4.13.9; 9.2.2(3); 9.2.2(5)....
- Norton 5600 Series Low Energy Operator
-
State Narrative Crash Data
For example, an officer may fail to notice that a child struck by a car was riding a scooter at the time, or may refer to the scooter in his report as a "push bike" or "skooter."...
-
Clear Ground Space [1011.2]
Fire rings, grills, fireplaces, and woodstoves 48 by 48 inches on all usable sides of a fire ring, grill, fireplace, and woodstove....
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
- Triumph Foundation
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
Flush Controls on Toilets
Flush controls shall be located on the open side of the water closet. . 1991 ADA Standards Water Closet Flush Controls shall be mounted on the wide side of toilet areas no more than...
-
R409.2 Where Required
Handrails shall be provided on both sides of ramps and stairways....