Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
Search Results "Parallel Parking Space"
-
Character Spacing: ADA Standard Section 703.5.8
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space...
- Magnuson Group BALLOON Outdoor Waste Receptacle
-
206.7.3 Incidental Spaces
206.7.3 Incidental Spaces....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
T210 Wheelchair Spaces
Under the 2016 Non-Rail Vehicle Guidelines, large non-rail vehicles must provide at least two wheelchair spaces, and small non-rail vehicles must provide at least one wheelchair space....
-
Passing Spaces [1017.4]
People using mobility devices also use passing spaces to turn around....
-
Accessible Path of Travel
The accessible path of travel must extend from the altered primary function area to site arrival points, including public sidewalks and parking and passenger loading zones provided on the...
-
410.3 Clear Floor Space
Clear floor space in platform lifts shall comply with 305....
-
410.3 Clear Floor Space
Clear floor space in platform lifts shall comply with 305....
-
209 Passenger Loading Zones
except those required to comply with 209.2.2 and 209.2.3, shall provide at least one passenger loading zone complying with 503 in every continuous 100 linear feet (30 m) of loading zone space...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
Check-Out Aisles and Sales and Service Counters
Where clear floor space for a parallel approach is provided, the accessible portion of the counter must be at least 36 inches long and no higher than 36 inches above the finish floor....
-
806.2.2 Exterior Spaces
806.2.2 Exterior Spaces. Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
1005.5 Turning Space
1005.5 Turning Space. At least one turning space complying with 304.3 shall be provided on fishing piers and platforms....
- Impact Recovery Systems Slow Stop Rebounding Bollard Video Presentation
- Impact Recovery Systems Slow Stop Rebounding Bollard - How Does It Work
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall comply with Section 11B-705.1.2.2.
-
F206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
206.7.3 Incidental Spaces