Accessible Routes within a Site [§206.2.2] At least one accessible route within the boundary of the site originating from site arrival points must connect all accessible buildings, facilities...
Search Results "Non-Elevator Building"
-
Accessible Routes within a Site [§206.2.2]
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
206.2.2 Within a Site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches...
-
c-ii
Is an elevator or lift provided? ...
-
For a new public building, if EV charging equipment is not installed at this time, what is the extent of the infrastructure that an installer is required to show for plan check review?
Some enforcement jurisdictions (primarily city- and county building departments) may have additional requirements....
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker.
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker.
-
F206.2.3 Multi-Story Buildings and Facilities
At least one accessible route shall connect each story and mezzanine in multi-story buildings and facilities. EXCEPTIONS: 1....
-
4.3.11.1(7)
(7) An elevator lobby when elevator shafts and adjacent lobbies are pressurized as required for smokeproof enclosures by local regulations and when complying with requirements herein for...
-
Limited-Use/ Limited-Application Elevators [§408]
Limited-Use/ Limited-Application Elevators [§408] LULA elevators are passenger elevators that are permitted in facilities where an accessible route between stories or mezzanines is not...
-
When Transfer Systems Are Used
A transfer system provides access to elevated play components without the use of a wheelchair or mobility devices....
-
T704 Announcement Systems
Stop request systems must provide audible and visible notification onboard the non-rail vehicle indicating that a passenger has requested to disembark at the next stop. See T704.3....
- Figure 1008.3.2 Transfer Steps – Drawing from the U.S. Access Board
-
1008.3 Transfer Systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with 1008.3. Advisory 1008.3 Transfer Systems....
-
1008.3 Transfer Systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with 1008.3. Advisory 1008.3 Transfer Systems....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_.
-
407.4.7.2 Keypads
Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot. The dot...
-
407.4.8.1.2 Location
Indicators shall be located above the car control panel or above the door.
-
11B-407.4.8.1.2 Location
Indicators shall be located above the car control panel or above the door.
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
409.2 Call Buttons
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309.