5c. Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____
Search Results "Golf Car Rental Area"
-
5c.
-
Door Protective and Reopening Device [4.10.6]
Door reopening devices must be able to detect obstructions without contact; otherwise, they can disrupt the balance of people using crutches or canes. They must stop and reopen doors...
-
11B-411.2.1.7.3 Assignment by security credential
If a security system or other form of access control system is provided, the audio output shall provide a verbal announcement and direction to the location of the access control...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
§ 38.101(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge...
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table...
-
§ 38.107 Restrooms
[See subsections ...]
-
§ 38.101 Lighting
[See subsections ...]
-
§ 38.113 Doorways
[See subsections ...]
-
§ 38.97 Interior circulation, handrails and stanchions
[See subsections ...]
-
11B-411.2.1.7.3 Assignment by security credential
If a security system or other form of access control system is provided, the audio output shall provide a verbal announcement and direction to the location of the access control...
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table...
-
407.4.8.1.4 Destination Indicator
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
F202.3 Alterations
Exception 4 does not require an outdoor recreation access route to altered elements and spaces in camping facilities, picnic facilities, viewing areas, or trailheads where the circulation...
-
Circulation Path
A person with disabilities is able to travel unassisted through that portion of the circulation path necessary to reach an area of refuge....
-
11B-407.4.8.1.4 Reserved.
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
11B-407.4.8.1.4 Reserved
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
4.3.11.3* Stairway Width
Each stairway adjacent to an area of rescue assistance shall have a minimum clear width of 48 inches between handrails....
-
1015.4 Turning Space
This section requires a turning space complying with 304.3 of the Architectural Barriers Act Accessibility Guidelines to be provided within the viewing area....
-
(4) Doors to public and common use areas