The surface is not firm and stable for a distance of 45 feet or more (14 m). Limiting Factor 3. ...
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
7.2.2.1 Determining Impracticability
-
1.1.3 Scope
this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building...
-
1.1.3 Scope
this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building...
-
1.1.3 Scope
this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building...
-
Light Rail Platform Slope
The Board has explicitly specified that rail platforms shall slope no more than 1:48 in any direction, consistent with cross slope provisions for walking surfaces in section 403....
-
Cells with Communication Features: ADA Standard Section 232.2.2
Section 232.2.2 covers scoping requirements in the current ADA Standards for cells with communication features.
-
11B-232.2.2 Cells with communication features
At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently...
-
Executive Summary
After traveling over each surface, subjects were asked to subjectively rate each surface and decide whether the surface was acceptable or not....
- Steelcase Series 5 Height-Adjustable Work Surface
-
Pemko 193 Slip resistance
Hello ETA, I see that you can ask for slip resistance by adding a coating to the Pemko 193 plate. Any experience with this application? Is this a permanent slip resistance or...
-
4.3.2(3)
(3) At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements and with all accessible dwelling units within the building...
- Access Board: Accessible Route Carpet
-
4.1.7(3)(b)
(b) At least one accessible entrance complying with 4.14 which is used by the public shall be provided. EXCEPTION: If it is determined that no entrance used by the public can...
-
4.1.7(2)(b)
(b) At least one accessible entrance which is used by the public complying with 4.14 shall be provided. EXCEPTION: If it is determined that no entrance used by the public can...
-
6.2.3 Bathing and Toilet Facilities Constructed at Beaches
Where bathing and toilet facilities are constructed at developed beach sites and pedestrian access points to the beach are provided near the bathing and toilet facilities, beach...
-
Where can one get further information or technical assistance on the IBC, including its requirements for means of egress?
Technical assistance on the IBC is available from the International Code Council (ICC) at (888) ICC-SAFE (422-7233) or by email at CareCenter@iccsafe.org . For further information,...
-
11B-306.2.3 Minimum required depth
The toe clearance shall extend 19 inches (483 mm) minimum under built-in dining and work surfaces required to be accessible. ...
-
Transfer Heights
Transfers to level surfaces require less exertion on the upper extremities [5, 10, 11]. Transfers are easiest and safest to obtain when they are as close to level as possible [6]....
-
207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
Has there been consideration for electric vehicles being parked in valet mode that could share EVSE and meet the equivalent EVSE option? This could reduce the cost of construction and major electrical upgrades.
Absent specific requirements, this situation would require the building official to determine the extent of applicable accessibility requirements on a case-by-case basis....
-
Non-Circular Cross Sections: ADA Standard Section 505.7.2
Section 505.7.2 covers the current ADA Standards for the non-circular cross section of handrail gripping surfaces.
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
13.1 Q. Are the public and common use areas of a newly constructed development that consists entirely of buildings having four or more multistory townhouses, with no elevators, required to be accessible?
Multistory townhouses, provided that they meet the definition of multistory in the Guidelines, are not covered multifamily dwellings if the building does not have an elevator....
-
11B-306.2.3 Minimum required depth
The toe clearance shall extend 19 inches (483 mm) minimum under built-in dining and work surfaces required to be accessible by Section 11B-226.1....