In addition to the compartments required to comply with Section 11B-604.8.1, where six or more toilet compartments are provided, or where the combination of urinals and water closets totals...
Search Results "Water Depth"
-
11B-213.3.1.1 Toilet compartments
-
11B-213.3.1.1 Toilet compartments
In addition to the compartments required to comply with Section 11B-604.8.1, where six or more toilet compartments are provided, or where the combination of urinals and water closets totals...
-
11B-604.8.1.4 Toe clearance
[2010 ADA Standards] EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches deep with a wall-hung water closet or 65 inches deep with...
-
11B-604.8.1.4 Toe clearance
[2010 ADA Standards] EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches deep with a wall-hung water closet or 65 inches deep with...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
Table 407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach Reach Depth Operable Part Height Less than 20 inches (510 mm) 48 inches...
-
Clear Floor Space [4.27.2]
controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed within niches or alcoves may require additional maneuvering space depending on the recess depth...
-
4.21.3 SEAT
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall. The seat shall be on the wall opposite the controls....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....
-
6.4.3
Normal recreation water level at lake, pond, and reservoir beaches....
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
Catch Pool
A pool or designated section of a pool used as a terminus for water slide flumes....
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
POWDER ROOM
A room containing a water closet (toilet) and a lavatory, and which is not defined as a bathroom....
-
POWDER ROOM
A room containing a water closet (toilet) and a lavatory, and which is not defined as a bathroom....
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
106.5.16 Catch Pool
A pool or designated section of a pool used as a terminus for water slide flumes....
-
11B-235.2.1 Dispersion
Types of boat slips are based on the size of the boat slips; whether single berths or double berths, shallow water or deep water, transient or longer-term lease, covered or uncovered; and...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
Requirement: 4.22.4, 4.23.4 Water Closets....