permitted to be 44 inches (1118 mm) minimum, if at least one turning space complying with Section 11B-304.3 is provided where the restricted accessible route exceeds 30 feet (9144 mm) in length...
Search Results "TTY Cord Length"
-
11B-1008.2.4.1 Ground level
-
11B-1002.4.4.2 Side entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
11B-1008.2.4.1 Ground level
permitted to be 44 inches (1118 mm) minimum, if at least one turning space complying with Section 11B-304.3 is provided where the restricted accessible route exceeds 30 feet (9144 mm) in length...
-
11B-411.2.3.1 Floor designation signs
The outside diameter of the star shall be 2 inches (51 mm) and all points shall be of equal length. Raised characters, including the star, shall be white on a black background....
-
604.5.2 Rear Wall
The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the...
-
1002.4.4.2 Side Entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
1002.4.4.2 Side Entry
For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering...
-
1008.2.4.1 Ground Level
shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with 304.3 is provided where the restricted accessible route exceeds 30 feet (9145 mm) in length...
-
406.7 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
1008.2.4.1 Ground Level
shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with 304.3 is provided where the restricted accessible route exceeds 30 feet (9145 mm) in length...
-
Meeting User Needs
healthcare facilities, such as Beechwood Home in Cincinnati, OH, (Dorsky Hodgson and Partners) to accommodate both younger and older adults with Multiple Sclerosis, Cerebral Palsy, and spinal cord...
-
Passenger Loading Zones
Accessible passenger loading zones must have an access aisle that is 60 inches wide minimum and extends the full length of the vehicle pull-up space....
-
5.4.1 Transfer Support Location for M301 and M302
Figure 5.4.1 Location and Length ofย Transfer Supports (SOURCE: Midmark Corporation) A: Table seat depth, 17 inches minimum B: Transfer support length, 15 inches minimum C: Distance...
-
Short Hikes and Interesting Features
Add together all the lengths of trail where technical requirements can't be met because of conditions for an exception....
-
Lift Compatibility (M301.4 and M302.4)
For example, full body bone densitometers usually have components that move beneath the length of the patient support surface and may prevent the equipment from meeting the technical criteria...
-
11B-1003.3.1 Boat slip clearance
Clear pier space shall be permitted to be 36 inches (914 mm) wide minimum for a length of 24 inches (610 mm) maximum, provided that multiple 36 inch (914 mm) wide segments are separated...
-
11B-1003.3.1 Boat slip clearance
Exceptions: Clear pier space shall be permitted to be 36 inches (914 mm) wide minimum for a length of 24 inches (610 mm) maximum, provided that multiple 36 inch (914 mm) wide segments...
-
1003.3.1 Boat Slip Clearance
Clear pier space shall be permitted to be 36 inches (915 mm) wide minimum for a length of 24 inches (610 mm) maximum, provided that multiple 36 inch (915 mm) wide segments are separated...
- American Academy of Physical Medicine and Rehabilitation (AAPM&R)
- Parents in Wheelchairs
- Behavioral Safety Products #DH410 Cylindrical Ligature Resistant Lever Handle
-
Availability of Copies and Electronic Access
Persons using a TTY should call (202) 272-5449. Please record a name, address, telephone number and request publication S-34....
-
EXTREME HEAT RESPONSE
Use the Cooling Center Finder (nyc.gov/beattheheat or call 311/TTY 212-639-9675) to find your nearest center....
-
ยง 35.104 Auxiliary aids and services
handset amplifiers, assistive listening devices, assistive listening systems, telephones compatible with hearing aids, closed caption decoders, open and closed captioning, text telephones (TTYs...