This drawing should show that the gutter is not included in the required min 18’ depth. The dashed lines don’t spell it out clearly enough to me.
Search Results "Exit Ramp"
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Interesting issue/drawing. If the slope of the gutter is greater than 1:48, can they merely show it outside of the required 18' deep accessible parking space and access aisle? If...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. Stroke...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms). Letters and numerals shall be raised 1/32 in, upper case, sans serif or simple serif type and shall be...
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
4.1.2(15)
(15) If signs are provided, they shall comply with 4.30.1, 4.30.2 and 4.30.3. In addition, permanent signage that identifies rooms and spaces shall also comply with 4.30.4 and...
-
4.30.4* RAISED CHARACTERS OR SYMBOLS
Letters and numbers on signs shall be raised 1/32 in (0.8 mm) minimum and shall be sans serif characters. Raised characters or symbols shall be at least 5/8 in (16 mm) high, but no...
-
11B-703.4 Installation height and location
11B-703.4 Installation height and location. Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
11B-703.5.7 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
Q2: Milling a Road Surface
Q2: The Joint Technical Assistance states that “[r]esurfacing is an alteration that triggers the requirement to add curb ramps if it involves work on a street or roadway spanning from one...
-
1008.4 Play Components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
1008.4 Play Components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....