If a new addition to a building or facility does not have an entrance, then at least one entrance in the existing building or facility shall comply with 4.1.4, Entrances....
Search Results "Building Official"
-
4.1.5(1) ENTRANCES
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
-
General: ADA Standard Section 208.3.1
Section 208.3.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for parking space locations.
- HEWI System Circum Handrails
-
ENTRANCE
Any access point to a building or portion of building or facility used for the purpose of entering....
-
§100.201 Premises
Premises means the interior or exterior spaces, parts, components or elements of a building, including individual dwelling units and the public and common use areas of a building....
-
206.4.7 Restricted Entrances
Where restricted entrances are provided to a building or facility, at least one restricted entrance to the building or facility shall comply with 404....
-
2. a. Accessible route into and throughout the facility
Accessible route into and throughout the facility - The following is a 4-point guideline for ensuring equal access from the parking lot, outdoor walkways, entrances and exists of the buildings...
-
11B-206.4.3 Entrances from tunnels or elevated walkways
Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway...
-
11B-206.4.3 Entrances from tunnels or elevated walkways
Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway...
-
11B-902.2.1 Overlap
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Section 11B-902.2 has been amended...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
FACILITY
All or any portion of a building, structure, or area, including the site on which such building, structure or area is located, wherein specific services are provided or activities performed...
-
USE OF THE WAY
The only standard building egress system that may require the ability to speak in order to evacuate a building is an emergency phone in an elevator....
-
4.1.3(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
4.1.3(8)(b)(i)
(i) In addition, if direct access is provided for pedestrians from an enclosed parking garage to the building, at least one direct entrance from the garage to the building must be accessible...
-
4.1.2(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
206.4.2 Parking Structure Entrances
Where direct access is provided for pedestrians from a parking structure to a building or facility entrance, each direct access to the building or facility entrance shall comply with 404...
-
101.1.2
101.1.2 All new or altered public buildings and facilities, private buildings and facilities, places of public accommodation, and commercial facilities subject to this code shall comply...