Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
Search Results "Toilet Room Configuration"
Commonly Searched Documents
-
11B-806.2.2 Exterior spaces
-
Personal Assistants and Service Animals
Personal Assistants Ensure seating plans include room for each assistant, both within meeting rooms and meal service areas....
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....
-
806.2.2 Exterior Spaces
Exterior spaces, including patios, terraces and balconies that serve the guest room shall be accessible....
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
224.2 Guest Rooms with Mobility Features
224.2 Guest Rooms with Mobility Features. In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2....
-
6.3(2)
In rooms with 2 beds, it is preferable that this space be located between beds....
-
§ 36.406(e)(2)
(2) Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in accordance with section 809.2 of the 2010...
- Access Board: Tactile Sign Clear Floor Space
-
11B-224.7.1 Multi-bedroom housing units with mobility features
Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in compliance with Section 11B-809.2....
-
Feature 3 - Building Entrance
Feature 3 - Building Entrance Signs for an alternate accessible entrance are posted at inaccessible entrances and key decision points along the accessible route. An...
-
Temporary Barrier Removal Suggestions for Accessible Features
Temporary Barrier Removal Suggestions for Accessible Features
-
Tips for Attendees
While there are standards to help ensure that meetings, events, and conferences are accessible to participants with a wide range of needs, the hard truth is that all systems are...
-
11B-219 Assistive listening systems.
[See subsections ...]
-
11B-219.1 General
Assistive listening systems shall be provided in accordance with Section 11B-219 and shall comply with Section 11B-706.
-
11B-219 Assistive listening systems
[See subsections ...]
-
11B-219.1 General
Assistive listening systems shall be provided in accordance with Section 11B-219 and shall comply with Section 11B-706.
-
9.4 Other Sleeping Rooms and Suites
Doors and doorways designed to allow passage into and within all sleeping units or other covered units shall comply with 4.13.5.