Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
Search Results "Maximum Dimension"
Commonly Searched Documents
-
1132A.6 Closer-effort to operate doors
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
11B-604.9.6 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
§8.23(b)(1)
(1) Subject to paragraph (b)(2) of this section, alterations to dwelling units in a multifamily housing project (including public housing) shall, to the maximum extent feasible, be made...
-
11B-604.7 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 _|Operation|_ and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
407.12.3.2.2 Knee and Toe Space
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of obstructions....
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
§ 38.83(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
§ 38.125(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum....
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical....
-
405.6 Rise
The rise for any ramp run shall be 30 inches (760 mm) maximum....
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum....
-
405.6 Rise
The rise for any ramp run shall be 30 inches (760 mm) maximum....
-
R407.6.1 Slope
Landing slopes shall be 2 percent maximum in any direction....
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz....