Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
Search Results "Counter Height"
-
11B-407.2.1.1 Height
-
11B-811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To see...
- Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
-
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces For imaging equipment with transfer surfaces, the Committee recommends a positioning support...
-
M305.1 General
Supports shall comply with M305.
-
M305.1 General (Section-by-Section Analysis)
This is an introductory section.
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF...
-
M305.1 General
Supports shall comply with M305, as applicable.
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
-
Food and Beverage Service
Accommodating Diners with Disabilities factsheet provides both legal standards and promising practices for paths of travel, approach to dining spaces, seating, dining table and service counter...
- American Standard Yorkville 1.6 gpf Right Height Elongated Pressure Assisted Toilet
-
Amusement Rides
Word Fillable Form (0.8MB) Word Non-Fillable Form (0.7MB) PDF Non-Fillable Form (0.5MB)
-
Examples of meeting your “access to goods and services” obligation when physical barrier removal is not readily achievable
In a different restaurant, it is not readily achievable to make counters accessible by lowering heights or providing an accessible counter or bar area....
-
Chapter 9: Built-In Elements
Chapter 9 covers built-in elements, including dining surfaces and work surfaces (902), benches (903), and sales and service counters (904)....
-
F. Check-In Areas
If a permanent reception counter is used for check in, make sure to provide a writing surface at an accessible height for people who use a wheelchair, scooter, or other mobility device....
-
E. Restaurants and Concessions:
PSE shall ensure that all moveable service counters provide service at the side of the stand....
-
Sections 5 Through 9 (Section-By-Section Analysis and Response to Comments)
At least one of each type of sales or service counter where a cash register is located shall be made accessible. Accessible counters shall be dispersed throughout the facility....