Operating Hardware Common Problem: The shape of the hardware on accessible doors, and on faucets, fixed lamps, drapery controls, and heating and air conditioning controls in spaces...
Search Results "Volume Control Symbol"
Commonly Searched Documents
-
Operating Hardware
-
Issue 4: Wrong pole! …Wrong message!
Figure 7: Installation where APS are installed in wrong locations; both are too far from street they control and will be heard as closer to the other street. ...
-
220 and 707 Automatic Teller Machines and Fare Machines
220 and 707 Automatic Teller Machines and Fare Machines Section 707 of the 2010 Standards adds specific technical requirements for speech output, privacy, tactilely-discernible input controls...
-
T704 Announcement Systems
Several commenters, including a public transportation organization, a transit agency, and individuals with disabilities, recommended that the Access Board include standards for the volume...
- Inclusion Solutions ADA Parking Mat
- Safety Step TD Parking Stall Mats
-
A4.27.3 HEIGHT
A6 further illustrates mandatory and advisory control mounting height provision for typical equipment....
-
Issue 13: Stub poles
In the location shown in Figure 15 (a pre-timed intersection), the APS was installed on the available mast arm pole, resulting in an installation in which the APS volume had to be set to...
-
11B-809.10.5.1 Clear floor space
Controls shall be located on the wall at the foot of the bathtub. The edge of the clear floor space shall be flush with the control wall surface....
-
Destination-Oriented Elevators
display of each floor a car has been programmed to stop at and automatic verbal announcement of each car stop are required Visual indicators: ½” min. character height, location above control...
-
Tactile arrow
Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and signals...
- Moen® Chrome PosiTemp® Shower Kit
-
Issue 11: Good vibrations (vibrotactile indications)
The vibrotactile indication can be turned off in some devices by a setting either on the control board or within the PDA device. Check settings to be sure vibration is on....
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 213.2
Section 213.2 covers scoping requirements in the current ADA Standards for toilet rooms and bathing rooms.
-
Issue 2: Location relative to the crosswalk
Since the APS is not close to the crosswalk and curb ramp, the volume of the audible walk indication and pushbutton locator tone must also be louder in order to be heard from the crossing...
-
§382.57(c)(6)(ii) Alphabetic keys
(ii) Alphabetic keys. Alphabetic keys must be arranged in a QWERTY keyboard layout. The “F” and “J” keys must be tactilely distinct from the other keys.
-
1. Accessible toilet
1. Accessible toilet with rear and side grab bars, clear floor space for wheelchair transfer, and an accessible flush valve.
-
1630.16(e)
(e) Infectious and communicable diseases; food handling jobs. --
-
Section 1630.16(e) Infectious and Communicable Diseases; Food Handling Jobs
Section 1630.16(e) Infectious and Communicable Diseases; Food Handling Jobs This provision addressing food handling jobs applies the “direct threat” analysis to the particular...
-
Issue 8: Rest-in-WALK (quiet time ok)
Issue 8: Rest-in-WALK (quiet time ok) In some locations, the pedestrian signals ‘rest-in-WALK’ and it may not be desirable to have the WALK indication repeat constantly during the...
-
Location
Location Pushbutton-integrated APS rely on relative proximity to the crossing location, not on difference in sounds, to clarify which street crossing is being signaled....
-
Toilet Rooms-Special Exhibit Space
Toilet Rooms-Special Exhibit Space: u. The force required to push or pull open the restrooms' vestibule doors is 10 lbf, which exceeds the maximum allowable door opening force of...
-
T505 Fare Collection Devices
[See subsections ...]