Understanding what the ADA requirements are for door threshold height modification and the products that are available for building and disability access code compliance....
Search Results "Shower Door"
Commonly Searched Documents
- SafePath: ADA Door Access - What is a Level Landing?
-
Entrance Landings
Entrance landings must accommodate door maneuvering clearances as well as landings for provided ramps. Entrance Landing...
- Aurora Doors Sliding Barn Door
- ACO Linear QuARTz Drain Promotional Video
-
§100.205(c)(2)
(2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and...
-
Problem Four (Entrance)
Problem Four: The entrance door has a door knob and/or latch that requires tight pinching and twisting and is not accessible....
-
2. b. WIDE AND EASY TO OPEN EXTERIOR AND INTERIOR DOORS
[See subsections ...]
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
- PC Doors Pocket Door EZ-Closer
-
F216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory F216.4.1 Exit Doors....
-
216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory 216.4.1 Exit Doors....
-
Door King Inc. 6400 In-Ground Gate Operators Video
Requires the Registered User plan or above. Login!
-
H5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
4.8.2 Clear Floor or Ground Space
The clear floor or ground space around outdoor rinsing showers shall be 60 inches (1525 mm) by 60 inches (1525 mm)....
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
Measuring Opening Force
Measuring Opening Force The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door...
-
Grab Bars [4.20.4] and Controls [4.20.5]
Recommendation: A hose for shower spray units longer than the required minimum of 60 inches is recommended for easier use of the shower spray unit from the seat....
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
- SOSS Door Hardware UltraLatch Demonstration Video
- AD Systems’ Exam Room Doors
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...