Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
Search Results "Maximum Extent Practicable"
-
11B-1009.5.7 Grab bars
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-703.4.1 Height above finish floor or ground
characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524 mm) maximum...
-
11B-1009.2.1 Pool lift location
Pool lifts shall be located where the water level is 36 inches (914 mm) minimum and 48 inches (1219 mm) maximum. [2010 ADA Standards] 1009.2.1 Pool Lift Location....
-
§8.56(a) Periodic compliance reviews
The responsible civil rights official or designee may periodically review the practices of recipients to determine whether they are complying with this part and where he or she has a reasonable...
-
Cognitive/Psychiatric Impairments
Some individuals with psychiatric impairments benefit from frequent emergency drills, but for others practice drills may trigger anxiety....
-
Capacity Constraints
The rule mentions three specific examples of operational patterns or practices that would violate this provision....
-
7. What remedies address violations of the ADA’s integration mandate in the context of disability employment systems?
Various indicators of integration are relevant to Olmstead employment remedies, such as individuals with disabilities’ interaction with non-disabled persons to the fullest extent possible...
-
§382.125(c)
return of passengers' wheelchairs, other mobility aids, and other assistive devices as close as possible to the door of the aircraft, so that passengers may use their own equipment to the extent...
-
Sec.36.308(a)(2)
(2) If removal of seats is not readily achievable, a public accommodation shall provide, to the extent that it is readily achievable to do so, a portable chair or other means to permit a...
-
§ 1194.2(a)(2)
an agency determines that compliance with any provision of this part imposes an undue burden, the documentation by the agency supporting the procurement shall explain why, and to what extent...
-
§ 35.151(b)(4)(iv)(A)
necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent...
-
§ 36.506 Alternative means of dispute resolution.
Where appropriate and to the extent authorized by law, the use of alternative means of dispute resolution, including settlement negotiations, conciliation, facilitation, mediation, factfinding...
-
§ 35.151(b)(4)(iv)(A)
necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent...
-
Appendix to §36.304(d) Compliance Dates and Applicable Standards for Barrier Removal and Safe Harbor
Applicable Standard Before March 15, 2012 Elements that do not comply with the requirements for those elements in the 1991 Standards must be modified to the extent...
-
11B-810.2.2 Dimensions
Access Board's Note to Reader: The Department of Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's...
-
11B-810.2.2 Dimensions
Access Board's Note to Reader: The Department of Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's...
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
11B-809.8.4 Door signal devices
The activating mechanism shall be mounted 48 inches (1219 mm) maximum above the floor and connected to permanent wiring....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-605.5.1 Urinal location
Urinals in compartments shall have the centerline of the urinal located 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition....