High efficiency ultra low consumption (1.1gpf/4.2Lpf), utilizes 31% less water Meets EPA WaterSense® criteria Combination bowl and tank, less seat 12" (305mm) rough...
Search Results "Fixed Seat"
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467136
-
General Requirements of Part 382
Carriers shall permit a service animal to accompany a qualified individual with a disability in any seat in which the person sits, unless the animal obstructs an aisle or other area that...
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
- Caroma® USA Sydney Smart II Elongated Toilet
-
Implication for Standards and Design
Close to 200 community dwelling adults who independently transfer have been evaluated during phases 1 and 2 combined of this multi-year study. The main difference between phase 1...
-
M302.4 Lift Compatibility
EXCEPTION: Where fixed overhead patient lifts are provided, and when their use with diagnostic equipment is permitted by an enforcing authority, diagnostic equipment shall not be required...
-
How to Measure Transfer Surface Height
Many medical examination rooms are equipped with fixed height examination tables, with a typical 32-inch seat height....
-
4.4.4 Clear Floor or Ground Space
Locate the clear space to provide shoulder alignment between a person sitting on the bench and a person seated in a wheelchair occupying the clear space....
-
T213.2 Priority Seats
Non-rail vehicles operated in fixed-route service shall designate at least two seats as priority seats for passengers with disabilities....
-
Plan 6A: 12-Foot Wide Accessible Guest Room
Furnishings include a king bed and additional seating. ...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
Features include a standard roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room....
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Plan 4A: 13-Foot Wide Accessible Guest Room
Features include a standard roll-in shower with a seat, comparable vanity, clothes closet with swinging doors, and door connecting to adjacent guest room....
-
III. Costs and Benefits
The Department estimates that the costs associated with this final rule will be minimal for two reasons. First, modifications to policies, practices, and procedures, if needed by an...
-
Positioning Supports Considered
panels with handholds to be provided along the sides of diagnostic equipment used by patients in a supine, prone or side-lying position, and diagnostic equipment used by patients in a seated...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....