Characters and symbols on buttons, where provided, shall be white on a black background.
Search Results "Elevator Exemption"
Commonly Searched Documents
- 
    
  
  11B-411.2.1.5.2 Color
  
 - 
    
  
  11B-1008.3.1.3 Transfer space
  
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform. The 48 inch (1219 mm) long minimum dimension of the transfer...
 - 
    
  
  11B-409.4.7.2 Operable parts
  
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
 - 
    
  
  11B-409.4.7.1 Type
  
A telephone and emergency signal device shall be provided in the car.
 - 
    
  
  11B-411.2.1.5.1 Size
  
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
 - 
    
  
  11B-407.4.8.2.3 Frequency
  
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
 - 
    
  
  11B-407.3.3.1 Height
  
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
 - 
    
  
  11B-407.4.6.4.1 Height
  
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
 - 
    
  
  11B-409.4.3 Platform to hoistway clearance
  
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
 - 
    
  
  11B-409.4.7.4 Cord
  
The telephone cord shall be 29 inches (737 mm) long minimum.
 - 
    
  
  11B-411.2.1.4.1.2 Identification
  
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
 - 
    
  
  11B-240.2.1.2 Additional number and types
  
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
 - 
    
  
  F240.2.1.2 Additional Number and Types
  
Where elevated play components are provided, ground level play components shall be provided in accordance with Table F240.2.1.2 and shall comply with 1008.4....
 - 
    
  
  240.2.1.2 Additional Number and Types
  
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 240.2.1.2 and shall comply with 1008.4....
 - 
    
  
  240.2.1.2 Additional Number and Types
  
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 240.2.1.2 and shall comply with 1008.4....
 - 
    
  
  11B-240.2.1.2 Additional number and types
  
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4. ...
 - 
    
  
  11B-240.2.1.2 Additional number and types
  
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
 - 
    
  
  9.2.2(2)
  
This is not intended to require an elevator in multi-story units as long as the spaces identified in 9.2.2(6) and (7) are on accessible levels and the accessible sleeping area is suitable...
 - 
    
  
  F203.6 Machinery Spaces
  
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
 - 
    
  
  203.5 Machinery Spaces
  
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
 - 
    
  
  11B-203.5 Machinery spaces
  
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
 - 
    
  
  11B-203.5 Machinery spaces
  
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
 - 
    
  
  4.10.12(2)
  
(2) Tactile, Braille, and Visual Control Indicators. All control buttons shall be designated by Braille and by raised standard alphabet characters for letters, arabic [sic]...
 - 
    
  
  203.5 Machinery Spaces
  
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...