Elevator car leveling shall comply with Section 11B-407.4.4....
Search Results "Altered Elevator"
-
11B-411.4.4 Leveling
-
Accessibility Standards in Title II Regulations Issued by DOJ
part, as discussed later in this section) incorporated by reference two sets of standards for new construction and alterations: UFAS and the 1991 Standards [21] without the “elevator exemption...
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems.
-
409.4.5 Illumination Levels
Elevator car illumination shall comply with 407.4.5....
-
Scope: ADA Standard Section 201.1
Section 201 discusses the scope of the ADA Standards.
-
F202.3.2 Extent of Application
An alteration of an existing element, space, or area of a building or facility shall not impose a requirement for accessibility greater than required for new construction....
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
101.2 Effect on Removal of Barriers in Existing Facilities
(3) Repositioning shelves; (4) Rearranging tables, chairs, vending machines, display racks, and other furniture; (5) Repositioning telephones; (6) Adding raised markings on elevator...
-
Section 36.405 Alterations: Historic Preservation (Section-By-Section Analysis and Response to Comments)
Section 36.405 Alterations: Historic Preservation (Section-By-Section Analysis and Response to Comments) Section 36.405 gives effect to the intent of Congress, expressed in section 504...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
Standards Applicable Under Section 504 as of March 15, 2012
In addition, effective March 15, 2012, because the 1991 Standards will no longer be an applicable standard under the ADA for any new construction and alterations, we are announcing that...
-
11B-202.5 Alterations to qualified historic buildings and facilities
Advisory 11B-202.5 Alterations to qualified historic buildings and facilities. ...
-
11B-202.5 Alterations to qualified historic buildings and facilities
Advisory 11B-202.5 Alterations to qualified historic buildings and facilities. ...
-
11B-202.5 Alterations to qualified historic buildings and facilities
Advisory 11B-202.5 Alterations to qualified historic buildings and facilities. ...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, public housing facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential...
-
Make Changes
Check whether local and state building codes require greater accessibility when alterations are undertaken....
-
Costs Not Monetized in the Formal Analysis
Entities covered by the final rules may choose to delay otherwise desired alterations to their facilities due to the increased incremental costs imposed by compliance with the new requirements...
-
Costs Not Monetized in the Formal Analysis
Entities covered by the final rules may choose to delay otherwise desired alterations to their facilities due to the increased incremental costs imposed by compliance with the new requirements...
-
Car Position Indicators [§407.4.8]
Car Position Indicators [§407.4.8] Position indicators are required for all cars, including those of 2-stop elevators....
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...