Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
Search Results "Seat Height"
Commonly Searched Documents
-
Characters: ADA Standard Section 707.7.2
-
Toilet Rooms-Special Exhibit Space
The toilet seat cover dispenser in the women's toilet room is located behind the toilet and is not mounted within the allowable reach ranges. See Standards §§ 4.2.5 and 4.2.6....
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum.
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings...
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings.
-
11B-704.4.1 Height
Exception: Where seats are provided, TTYs shall not be required to comply with Section 11B-704.4.1. Advisory 11B-704.4.1 Height....
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum....
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
All other diagnostic equipment used by patients seated in a wheelchair must comply with the other equipment clearances requirements....
-
Base Support [No specific provision—affects M303.2.4]
To discuss the maximum base support height, the sub-committee looked at anthropomorphic data regarding footrest heights....
-
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
-
§ 35.138 Ticketing
§ 35.138 Ticketing.
-
5.8.1 Wheelchair Spaces on Raised Platforms Recommendations
5.8.1 Wheelchair Spaces on Raised Platforms Recommendations Description: Proposed section M303 provides technical criteria for diagnostic equipment used by patients seated in a wheelchair...
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
and Toe Clearance Recommendations under Breast Platform Recommendations Description: The knee and toe clearance under the breast platform applies to mammography equipment for patients seated...
- Whitehall Mfg. Ligature Resistant Toilet Top Supply On-Floor
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
F202.6.5.5 Assembly Areas
Assistive listening systems shall comply with F219 and assembly seating shall comply with F221....
-
11B-219.5 Permanent and portable systems
Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating...
-
11B-219.5 Permanent and portable systems
Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating...
-
11B-219.5 Permanent and portable systems
Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating...
- American Standard Madera 1.28 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System