Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
Search Results "Floor Plan"
Commonly Searched Documents
-
11B-305.7.2 Parallel approach
- Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach – Drawing from the U.S. Access Board
- Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units – Drawing from the U.S. Access Board
- Figure 407.4.1(b) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(e) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(d) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(c) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach – Drawing from the U.S. Access Board
- Figure 407.4.1(a) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Access Board: Clear Floor or Ground Space
-
1(1)(b) Multiple entrances
Only one entrance is required to be accessible to any one ground floor of a building, except in cases where an individual dwelling unit has a separate exterior entrance, or where the building...
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
Inclusive Event Procedures for Emergencies
Contents Applying Emergency Planning Strategies - Safety Considerations for Site Selection - Projecting Numbers of Attendees with Disabilities Inclusive Safety information for...
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
Community Emergency Planning in NYC - A Toolkit for Community Leaders
[See subsections ...]
-
Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
The IBC contains requirements for exit stairway enclosures that address fire-resistance and smoke protection, stairways and handrails, signs, and other features. The ADA...
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
4.35.4 Bench
The bench shall be mounted 17 in to 19 in (430 mm to 485 mm) above the finish floor....