5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
Search Results "Seating Space"
Commonly Searched Documents
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations The Committee recommends a minimum two-inch high edge protection on both sides of the...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side.
-
11B-502.3 Access aisle
Access aisles serving parking spaces shall comply with Section 11B-502.3. Access aisles shall adjoin an accessible route....
-
4.7.8 Utility and Dump Station Hookup Clear Floor or Ground Space
The clear space shall be located with the long side of the space adjoining or overlapping an accessible parking space or accessible pull-up space for recreational vehicles, or an ORAR connecting...
-
Door Swing: ADA Standard Section 803.3
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....
-
Dishwasher: ADA Standard Section 804.6.3
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-802.1.2 Width
A single wheelchair space shall be 36 inches (914 mm) wide minimum....
-
1002.4 Wheelchair Spaces in Amusement Rides
1002.4 Wheelchair Spaces in Amusement Rides. Wheelchair spaces in amusement rides shall comply with 1002.4....
-
11B-608.2.2.1 Clearance
minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat...
-
Openings, Width and Length of Wheelchair Space
Openings, Width and Length of Wheelchair Space Openings and the width and length of wheelchair spaces need to be considered in relation to each other....
-
M302.1 General
Where diagnostic equipment is used by patients in a seated position, it shall comply with M302....
-
11B-802.1.2 Width
Where two adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (838 mm) wide minimum. Advisory 11B-802.1.2 Width....
-
806 Transient Lodging Guest Rooms
The Department’s drawings are sample plans, showing the layout of the space, relationship of elements to each other, and required clear floor and turning spaces....
-
11B-802.1.2 Width
Where two adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (838 mm) wide minimum. Advisory 11B-802.1.2 Width. ...
-
11B-203.4 Limited access spaces
Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible...
-
804.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
804.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....