Where ICT displays or processes video with synchronized audio, ICT shall provide a mode of operation that plays associated audio description....
Search Results "Power Operated Door"
-
412.1 General
-
§382.7(b)
(b) If you are a foreign carrier, this part applies to you only with respect to flights you operate that begin or end at a U.S. airport and to aircraft used for these flights....
-
§ 38.153 Doors, steps and thresholds
[56 FR 45756, Sept. 6, 1991, as amended at 63 FR 51698, 51702, Sept. 28, 1998]
-
11B-707.9.1, 11B-707.9.2 Point-of-sale devices
Removes and relocates to 11B-707.3 requirements specific to operable parts....
-
f-vi
Are the controls and operating mechanisms usable with one hand without tight grasping, pinching, or twisting? [ADA Standards §§ 4.11.2, 4.27.4] Yes No...
-
6e.
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? Yes _____ No _____...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
Kickplates
Kickplates Recommendation: Some people with disabilities may use walkers or wheelchair footrests to push through doors, particularly those with closers....
- Panda S.66 Solid Wood Folding Door System
- Panda S.51 All Aluminum Folding Door System
-
In-swinging Bathroom Doors
The commenter recommended that in-swinging doors be prohibited unless there is sufficient internal bathroom space, exclusive of the swing of the door, which allows either a five foot turning...
- LaCantina Doors Industrial Commercial - Best in Show Award Chicago AIA
-
f-v
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
-
402.2.2 Braille Instructions
Where speech output is required by 402.2, braille instructions for initiating the speech mode of operation shall be provided....
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
302.2 With Limited Vision (Section-by-Section Analysis)
With Limited Vision (Section-by-Section Analysis) This section proposes to revise the functional performance criterion for users with limited vision so that, where a visual mode of operation...
-
T304.3 Location
Operable parts provided at a wheelchair space shall be located adjacent to the wheelchair space 24 inches (610 mm) minimum and 36 inches (915 mm) maximum from the rear of the wheelchair...
-
4.34.2(6)
(6) Doors to and in accessible spaces that are intended for passage shall comply with 4.13, except that the provisions of 4.13.9 apply only to the doors at accessible entrances to the unit...
-
7a.
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Stds 4.1.3(7), 4.13.5] Yes _____ No _____...
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
g-i
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Standards §§ 4.1.3(7), 4.13.5] Yes No...
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....