Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
Search Results "Non-Elevator Building"
Commonly Searched Documents
-
11B-407.4.6.4.1 Height
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
5. Is a talk tube where two children talk to each other simultaneously considered one or two play components? If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?
If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?...
-
11B-216.1 General
Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with Section 11B...
-
Additional Number and Types: ADA Standard Section 240.2.1.2
Section 240.2.1.2 covers scoping requirements in the current ADA Standards for additional number and types of ground level play components.
-
11B-240.2.1.2 Additional number and types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
-
Machinery Spaces: ADA Standard Section 203.5
Section 203.5 covers scoping requirements of general exceptions for machinery spaces in the most current ADA Standards.
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
-
Alterations [§206.4 and §202.4]
destroy a facility’s historic significance (as determined by the appropriate State Historic Preservation Official or Advisory Council on Historic Preservation), access can be provided to a non-public...
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
4.1.2(5)
(5) One passenger elevator complying with 4.10 shall serve each level in all multi-story buildings and facilities....