Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges.
Search Results "Lawn Seating"
Commonly Searched Documents
- 
    
  
  M305.2.5 Surface Hazards
  
 - 
    
  
  M305.2 Transfer Supports
  
Transfer supports shall comply with M305.2.
 - 
    
  
  M305.2 Transfer Supports (Section-by-Section Analysis)
  
This is an introductory section. As discussed above in Section IV.E.1. (Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and...
 - 
    
  
  M305.2.5 Surface Hazards (Section-by-Section Analysis)
  
The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports. No public comments were submitted on this issue, but the MDE...
 - 
    
  
  5.4 Transfer Supports
  
5.4 Transfer Supports.
 - 
    
  
  5.4 Transfer Supports Recommendations
  
5.4 Transfer Supports Recommendations
 - 
    
  
  M305.2 Transfer Supports
  
Transfer supports shall comply with M305.2.
 - 
    
  
  § 35.138(h) Prevention of fraud in purchase of tickets for accessible seating
  
(h) Prevention of fraud in purchase of tickets for accessible seating....
 - 
    
  
  Does a wheelchair user have to use the seat belt and shoulder harness?
  
Transit operators may establish a policy that requires the seat belt and shoulder harness to be used by all riders, including those who use wheelchairs as well as those who use vehicle seats...
 - 
    
  
  Wheelchair seating locations must be provided in all areas
  
• Wheelchair seating locations must be provided in all areas including sky boxes and specialty areas....
 - 
    
  
  II. ENFORCING THE ADA PART 2
  
seating is sold out....
 - 
    
  
  § 35.138(h) Prevention of fraudulent purchase of accessible seating
  
(h) Prevention of fraudulent purchase of accessible seating. A public entity may not require proof of disability before selling a wheelchair space....
 - 
    
  
  M305.2.2.1 End Transfer Supports
  
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
 - 
    
  
  M305.2.4.1 Circular Cross Section
  
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
 - 
    
  
  M305.2.1.2 Side Transfer Supports
  
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
 - 
    
  
  M305.2.1.1 End Transfer Supports
  
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
 - 
    
  
  M305.2.2.2 Side Transfer Supports
  
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
 - 
    
  
  Requirement 6 -- Reinforced Walls for Grab Bars
  
[See subsections ...]
 - 
    
  
  1.18 Wheelchair space, wheelchair location, or wheelchair seating
  
1.18 "Wheelchair space," "wheelchair location," or "wheelchair seating" shall mean and refer to a designated space in an auditorium where a person who uses a wheelchair or motorized scooter...
 - 
    
  
  M305.2.4.2 Non-Circular Cross Section
  
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
 - 
    
  
  5.1.3 Transfer Surface Low Height Options for M301 and M302
  
5.1.3 Transfer Surface Low Height Options for M301 and M302 The Committee did not agree on a final low height recommendation. Rationale for final recommendation (more detail...
 - 
    
  
  5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
  
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
 - 
    
  
  5.1.3 Transfer Surface Low Height
  
5.1.3 Transfer Surface Low Height. No agreement on final low height
 - 
    
  
  5.1.2 Transfer Surface High Height
  
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.