(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal.
Search Results "Emergency Call System"
-
4.28.3(8)
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
8.2.1 Participants
8.2.1 Participants Forty-nine adult listeners with sensorineural hearing loss participated in this study. They were divided into six groups according the degree and configuration...
-
3.2 Microphone Location
3.2 Microphone Location There are no standards for microphone placement in live performances. The actual location appears to be a pragmatic mix composed of production...
-
5.2 Distributing Receivers
5.2 Distributing Receivers The same individual in the same physical location in a venue should be responsible for both checking in and checking out of the...
-
§ 37.73 Purchase or lease of used non-rail vehicles by public entities operating fixed route systems
[See subsections ...]
-
Reservation Systems Requirements for Places of Lodging
reservation is made for an accessible guest room, the specific accessible guest room reserved must be held for the reserving customer and the room must be removed from the reservation system...
-
7. INSTALLATION
While the different ALS and venues will require different depths and ranges of competencies, all require some minimum of information if the system is to be installed correctly....
-
2.2.3 Receivers
2.2.3 Receivers The receivers for FM assistive listening systems are basically FM radios "tuned" to the transmitting frequency....
-
H. Repairing and Rebuilding
Emergencies and disasters often damage state and local government facilities....
-
A. Fire Alarms
If the building has an audible fire alarm system, do each of the following rooms in the hotel have a visual alarm strobe light mounted on the wall at 80" above the floor to alert deaf persons...
-
3.2.6 Identification of Accessible Camping Units
Identification of accessible camping units is not required where camping units are assigned upon arrival or through a reservation system. ...
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
Areas of refuge are fire-resistance rated and smoke protected areas where those unable to use stairs can register a call for evacuation assistance and await instructions or assistance....
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
- inLOOP Personal Loop Portable Assistive Listening System
-
Question 22
YES/NO 22. Are there any obstacles that block access to lift or elevator controls? Obstacles may include trash receptacles or cigarette...
-
11B-1008.2.4.2 Elevated
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....
-
§ 37.185 Fleet accessibility requirement for OTRB fixed-route systems of large operators
Each large operator subject to the requirements of §37.183 shall ensure that--
-
General: ADA Standard Section 702.1
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...
-
708.4.1 Common Use or Public Use System Interface
708.4.1 Common Use or Public Use System Interface....
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA 72 and which shall [sic] activated upon initiation of the fire alarm system...
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
impaired, shall be provided with notification appliances for the hearing impaired installed in accordance with NFPA 72 and which shall [sic] activated upon initiation of the fire alarm system...
-
§ 38.23(d)(3) Mobility aids accommodated
The securement system shall secure common wheelchairs and mobility aids and shall either be automatic or easily attached by a person familiar with the system and mobility aid and having...
-
1008.2.4.2 Elevated
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....