In the 2016 Non-Rail Vehicle Guidelines, passenger access routes (which were referred to as “accessible circulation paths” in the proposed rule) must provide clearances sufficient to permit...
Search Results "Commuter Rail Car"
-
T503 Passenger Access Routes
-
11B-502.3.4 Location
For this reason, where a van and car share an access aisle, consider locating the van space so that the access aisle is on the passenger side of the van space....
-
11B-502.3.4 Location
For this reason, where a van and car share an access aisle, consider locating the van space so that the access aisle is on the passenger side of the van space....
-
11B-502.3.4 Location
Where a van and car share an access aisle, the van space must be located with the access aisle on the passenger side of the van space. ◼...
-
Brief Answers
Yes, the replacement of a staircase is an alteration under the ADA and DOT’s implementing regulations because a staircase replacement is tantamount to the renovation,...
-
Questions presented:
Is the replacement of a staircase at an existing public transportation facility an “alteration” that affects or could affect the usability of a facility for purposes of the ADA...
-
May a transit operator deny boarding to a rider whose wheelchair is difficult to secure?
No. If the transit operator has a policy that requires securement, or if a rider asks that the wheelchair be secured, Section 37.165(f) of the DOT ADA regulations requires...
-
May a transit operator deny boarding to a rider whose wheelchair is difficult to secure?
No. If the transit operator has a policy that requires securement, or if a rider asks that the wheelchair be secured, Section 37.165(f) of the DOT ADA regulations requires transit...
-
§ 38.55(b)
(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with...
- Filter Pave™ Porous Paving for Stormwater Management Informational Video
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1).
-
e-vii
e-vii. Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Standards § 4.10.13] Yes No
-
e-v
e-v. Are raised letters and Braille characters used to identify each floor button and each control? [ADA Standards § 4.10.12] Yes No
-
§ 36.304(b)(18)
(18) Creating designated accessible parking spaces;
-
§ 36.304(b)(6)
(6) Adding raised markings on elevator control buttons;
-
Sec.36.304(b)(6)
(6) Adding raised markings on elevator control buttons;
-
Sec.36.304(b)(18)
(18) Creating designated accessible parking spaces;
-
5f.
5f. Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Stds 4.10.13]
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
F208 Parking Spaces