Vibrotactile WALK indications Vibrotactile indications are transmitted by a vibrating plate or arrow on the housing of the pedestrian pushbutton. During WALK, the arrow or plate...
Search Results "CDC: Centers for Disease Control and Prevention"
Commonly Searched Documents
-
Vibrotactile WALK indications
-
Issue 12: Audible beaconing
Issue 12: Audible beaconing Audible beaconing -- providing a louder audible WALK signal in order to provide directional guidance to pedestrians who are blind -- is not needed at...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Issue 14: Inspection of contractor’s work - Beware of field changes! Figure 18: APS and curb ramps that were not installed as designed. Figure 19: Another view of the...
-
F229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. In accessible rooms or spaces, each glazed...
-
229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required by an...
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
Toilet Rooms North (Celebrity Spies)–Women [sic]: ff. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door...
-
§27.71(k)(4) Privacy.
(4) Privacy. Automated airport kiosks must provide the opportunity for the same degree of privacy of input and output available to all individuals. However, if an option is provided...
-
§ 27.71(k)(4) Privacy
(4) Privacy. Automated airport kiosks must provide the opportunity for the same degree of privacy of input and output available to all individuals. However, if an option is provided...
-
229.1 General
229.1 General. Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309 _|Operable Parts|_. Each glazed...
-
§ 38.123(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches. Doorways on the side wall shall have a minimum clear...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309. Each glazed opening required by...
-
11B-607.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
- TownSteel CD/CDC Series, Grade 1 Cylindrical Locks
- Viking Talk-A-Phones ETP-400V and ETP-400DV, Panel Phone E-1600A-TP-EWP
-
Keypads: ADA Standard Section 407.4.6.3
Section 407.4.6.3 covers the current ADA Standards for elevator car control keypads.
-
11B-404.2.7 Door and gate hardware
The lever of lever actuated latches or locks must be curved with a return to within ½ inch of the door to prevent catching on the clothing of persons during egress. ◼...
-
11B-404.1 General
A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”....
-
§27.71(k)(3)(iii) Status Indicators.
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§ 27.71(k)(3)(iii) Status indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
- Viking E-1600-20A Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-03B Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-03B-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
-
Significant alternatives which minimize any significant economic impacts on small entities
Maximum cross slope of 2 percent required on pedestrian access routes, including within pedestrian street crossings with yield or stop control....