408.3.2.1 Power Operation. Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced...
Search Results "Visible Signal (Elevator Landing)"
Commonly Searched Documents
-
408.3.2.1 Power Operation
-
408.3.2.2 Duration
408.3.2.2 Duration. Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
Call Button Clear Floor Space
...are all of the elevator lobbies free of ash trays or other elements placed below the elevator call buttons that project more than 4"?...
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay. ...
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADA Standards] 407.3.5 Door Delay....
-
F206.2.16.1 Ground Level and Elevated Play Components
The accessible route shall connect ground level play components required to comply with F240.2.1 and elevated play components required to comply with F240.2.2, including entry and exit points...
-
206.2.17.1 Ground Level and Elevated Play Components
The accessible route shall connect ground level play components required to comply with 240.2.1 and elevated play components required to comply with 240.2.2, including entry and exit points...
-
1007.6 Areas of refuge
Every required area of refuge shall have direct access to an enclosed stairway complying with Sections 1007.3 and 1019.1 or an elevator complying with Section 1007.4....
-
Play Components: ADA Standard Section 240.2
Section 240.2 covers scoping requirements in the current ADA Standards for play components.
-
1.9.1.2.3
1.9.1.2.3 Any curb or sidewalk intended for public use that is constructed in this state with private funds.
-
11B-408.4.3 Platform to hoistway clearance
The platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
11B-240.2 Play components
Where provided, play components shall comply with Section 11B-240.2.
-
1.9.1.2.4
1.9.1.2.4 All existing privately funded public accommodations when alterations, structural repairs or additions are made to such public accommodations as set forth under Chapter 11B.
-
4.3.11.1(7)
(7) An elevator lobby when elevator shafts and adjacent lobbies are pressurized as required for smokeproof enclosures by local regulations and when complying with requirements herein for...
-
11B-411.2.3.1 Floor designation signs
Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....