Different requirements apply to various types of signs: 1) Signs designating permanent rooms and spaces (e.g. , men's and women's rooms, room numbers, exit signs) must have raised and...
Search Results "Guest Room Configuration"
Commonly Searched Documents
-
III-7.5165 Signage
-
Universal Design for Health Care Facilities
Universal Design for Health Care Facilities: Addressing Safety, Access to Care for a Diverse Patient Population Environment of Care® News, January 2009, Volume 12, Issue...
- Like the Mic
- Bobrick Accessibility Video -- Mounting Height and Reach Ranges
-
Style: ADA Standard Section 703.5.3
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
General: ADA Standard Section 703.1
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4. Advisory 11B-202.2 Additions. An...
-
Telephones
Note: Technology is constantly changing and many of the tools listed below are gradually being replaced by newer devices. For the most up-to-date details on regulations, proposed...
-
Recessed Lavatories
Recessed Lavatories Recessing lavatories can provide space for side transfers while allowing a narrower room width....
-
Plumbing/Restrooms
PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
-
23. ROOM UPGRADE POLICY AT ALL BRAND HOTELS
ROOM UPGRADE POLICY AT ALL BRAND HOTELS....
-
Clear floor space at Lav
Terry, You should identify the minimum dimensions of the clear floor space at the Lav.
-
B. Accessible Routes To All Service/Activity Areas
includes people who use mobility devices, such as wheelchairs and scooters, being able to get to locations where supplies are distributed, to eating areas, to sleeping areas, to toilet rooms...
-
307.4 Vertical Clearance
307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80...
-
307.4 Vertical Clearance
Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The...
-
Vertical clearance and protruding objects
• Entrances and aisles with adequate head clearance and minimal projections into the path of travel result in easier navigation for people with lessened visual acuity or those who...
-
307.4 Vertical Clearance
Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm) high. The...
-
4.1.6(3)(e)(iii)
(iii) When existing toilet or bathing facilities are being altered and are not made accessible, signage complying with 4.30.1, 4.30.2, 4.30.3, 4.30.5, and 4.30.7 shall be provided...