Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
Search Results "Exterior Exit Stairway"
-
503.5 Vertical Clearance
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
§ 36.207(b)
used to enter the place of public accommodation, including the homeowner´s front sidewalk, if any, the door or entryway, and hallways; and those portions of the residence, interior or exterior...
-
4.13.8* Thresholds at Doorways
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
4.13.8* THRESHOLDS AT DOORWAYS
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
§ 38.113(e) Signage
The International Symbol of Accessibility shall be displayed on the exterior of all doors complying with this section unless all cars and doors are accessible and are not marked by the access...
- Kawneer North America 1040 Sliding Mall Front Door
- Landscape Forms Inc. Austin Bench Collection
- American Specialties Heavy Duty Stainless Steel Soap Dish with Rectangular Solid Bar 0398
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
USE ZONE
structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting...
-
M303.2.6 Edge Protection
more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side not providing entry to or exit...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway. 3. ...
-
505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 General 11B-502 Parking Spaces 11B-503 Passenger Drop-Off and Loading Zones 11B-504 Stairways...
-
Vertical Clearance [§307.4]
Fixed barriers, such as guardrails, are required where the vertical clearance is less than 80” such as at open stairways and along sloped or curved walls....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway. 3....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway....
-
F211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with F211....
-
Clear Floor or Ground Space [4.31.2], Mounting Height [4.31.3]
Where multiple banks are provided on a floor (or exterior site), at least one accessible phone must provide a forward approach (considered more convenient in the use of phones)....
-
1.1.3
1.1.3 A maximum overall design running slope for exterior accessible surfaces (other than ramps), such as sidewalks, of 4% (approximately 1:25) is recommended....
-
217 Telephones
Revisions made in finalizing the guidelines include: clarifying coverage of courtesy phones (217.1) applying requirements for wheelchair accessible telephones to exterior sites (...
-
211 Drinking Fountains
Scoping requirements apply where drinking fountains are provided on exterior sites, on floors, and within secured areas....