Search Results "Court Floor Holding Cell"
- Nystrom Building Products MatDesign Roll-Up Mats Vinyl Tread Section
-
Nystrom Building Products MatDesign Roll-Up Mats Rugged Scrub® Tread Section
Requires the Premium User plan or above. (Login or upgrade your account!)
-
407.4.1 Car Dimensions
[ECTCR UFAS 4.10.9, Fig. 22] EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth...
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
§ 38.159(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches (75 mm) or less above a 6 inch (150 mm) curb, a maximum slope of 1:4 is permitted; if the height of the vehicle...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
Station platforms
Station platforms must be coordinated with the vehicle floor height. (DOT ADA Standard 810.5.3.)...
- Disabled Sports USA
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor...
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
606.2 Clear Floor Space
606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
5.3.5 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1. ...
- ADA25: #12 of 25 -- Court Access
-
5.1.9 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4. ...
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
