Section 607.5 covers the current ADA Standards bathtub controls.
Search Results "Urinal Rim Height"
-
Controls: ADA Standard Section 607.5
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
AVAILABLE DATA DO NOT SUPPORT DEPARTING FROM THE CURRENTLY ACCEPTED STANDARD OF 19-INCH TRANSFER SURFACE HEIGHT
In evaluating data about seat height, the Committee took into account the relevant transfer height from the wheelchair....
-
Why a smooth surface door or kickplate is important
Remember that the latch that hits the push rim is nicking the surface your fingers have to grasp thousands of times a day for years....
- American Standard Yorkville 1.6 gpf Right Height Elongated Pressure Assisted Toilet
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface...
-
4.31.3* Mounting Height
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...