There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
Search Results "Standing Surface"
Commonly Searched Documents
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
-
6.8.2 Grade and cross slope
Where the surface is paved or is elevated above the natural ground, the surface shall not be steeper than 1:48 (2 percent) in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
- GE Profile™ Series 30" Slide-In Double Oven Electric Convection Range PS950EFES
-
Problem Three
Problem Three: Accessible parking spaces or access aisles are on a sloped surface and do not provide a level area for a safe transition from the voter’s car to a wheelchair....
-
Boston Center for Independent Living, Inc.
cancer that may have been detected had she not avoided a precautionary exam in part because of the anticipated humiliation of having to explain—yet again— that as a paraplegic she could not stand...
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
This section requires fire building surfaces to be 9 inches minimum above the ground, and cooking surfaces to be 15 inches minimum and 34 inches maximum above the ground....
-
Cross Slope
Comment. Comments indicated that specifications for cross slope (1:48 maximum) are not referenced in the curb ramp section. Response. In the final rule, the Board has clarified...
-
1011.4.1 Height
The tops of picnic tables shall comply with 902.3.
-
Handrails
...are there handrails on both sides of the stair at a uniform height of 34"-38" above the front edge of the step? [ADA Stds. 4.9] Yes __ No __ N/A __ Comments:...
-
A5. Accessible Parking Spaces
A5. Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions? [ADA Stds 4.6.3] If No: Look for a nearby area that is relatively...
-
1011.4.1 Height
The tops of picnic tables shall comply with 902.3.
-
1.2.3 Landings
1.2.3 Landings. Both measurements of ramp landings as described in Section 1.1.15 should not exceed a plus tolerance of 0.5%.
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope. The...
- Smith System Husky Clover Activity Table
- Sears Brands, LLC Craftsman 24 in. Digital LaserTrac® Level
- M-D Building Products, Inc. GEN2 SmartTool™ Digital Level
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
Resting Intervals on Trails
, fiberglass, or other manufactured material), it’s more difficult to ensure drainage on natural or gravel surfaces....
- Bosch Power Tools - GPL-3 3 Point Laser
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....