1016.8.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. ...
-
Section 4.26.2
• Section 4.26.2 of the 1991 Standards requires handrail gripping surfaces to have a diameter of 1 ¼ inches to 1 ½ inches, or to provide an equivalent gripping surface....
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
- Populas Vox Perfect Corner Workstation
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size...
-
Assumptions
Assumptions Two industry standard specifications are used to determine the safety and accessibility of each surface: ASTM F1292‒99/04 Standard Specification for Impact Attenuation of...
-
Q9: Pavement Preservation Treatment Types
Q9: Several pavement preservation treatment types are not listed in the technical assistance. If the treatment type is not specifically on the list of maintenance treatments, is it...
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
onto one short side (depth) and one long side (width) of the surface, and provide unobstructed transfer to the surface....
-
T208.1 General
A passenger access route shall consist of a route complying with T208.2 between wheelchair spaces and doorways, walking surfaces complying with T302, and clearances complying with T504....
-
1. Desk size
Desk size: If provided, the writing surface of desks and writing tables is no higher than 34 inches....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
- GE® 30" Slide-In Electric Convection Range JS750EFES
-
(2) Adjustability: Minimum Low Transfer Height
These commenters explained the delay in diagnosis and treatment when patients are unable to transfer from their wheeled mobility device to the examination surface and are inadequately examined...
- Smith System Husky Square Activity Table
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
- Smith System Trespa Planner Science Table 48″ Deep
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...