criteria in the proposed standards are based on the 2004 ADA and ABA Accessibility Guidelines: • Height of transfer surfaces on diagnostic equipment used by patients in a supine, prone, or side-lying...
Search Results "Side Reach"
-
2004 ADA and ABA Accessibility Guidelines
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed....
-
1013.2 Clear Ground Space
This section requires a clear ground space 4 feet wide minimum to be provided on all usable sides of tent pads and tent platforms to enable individuals who use wheeled mobility devices to...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed....
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
404.2.4.1 Swinging Doors and Gates
front Push 48 inches (1220 mm) 0 inches (0 mm)1 From hinge side Pull 60 inches (1525 mm) 36 inches (915 mm) From hinge side Pull...
-
404.2.4.1 Swinging Doors and Gates
Push 48 inches (1220 mm) 0 inches (0 mm)1 From hinge side Pull 60 inches (1525 mm) 36 inches (915 mm) From hinge side Pull 54 inches...
-
404.2.4.1 Swinging Doors and Gates
Perpendicular to Doorway Parallel to Doorway (beyond latch side unless noted) From front Pull 60 inches (1525...
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
Elevator Operable Parts
These controls should be held to the basic reach range specifications in section 308 like any other operable part, according to commenters. Response....
-
Maintaining Accessibility in Museum Shops
Staff should know how to assist people who need help in reaching or seeing merchandise....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
- TAYLOR Point of Sale Mounting Stands Solutions
-
11B-904.5.1 Self-service shelves and dispensing devices
Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall comply with Section 11B-308 _|Reach Ranges|_....
-
11B-904.5.1 Self-service shelves and dispensing devices
Self-service shelves and dispensing devices for tableware, dishware, condiments, food and beverages shall comply with Section 11B-308 _|Reach Ranges|_....
-
2.2 Key Measurement Variables and Procedures
Reaches and lifts: One-handed maximum reaches recorded at 5 different heights in three different directions for up to four different weight conditions (maximum of 60 reaches total). 4...
-
Clear Ground Space [1013.2]
A clear ground space at least 48 inches wide must be provided on all usable sides of tent pads and tent platforms....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
Standing Supports (M304.3 and M305.3)
Rationale: Standing supports required on one side of dual ramp has relevance for users being able to access either side for entry – user may only have one usable side due to condition such...
- Olympia i2 Single Handle Pull-Down Kitchen Faucet K-5020
