grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with the front end positioned...
Search Results "Horizontal Position"
-
11B-604.5.1 Side wall
-
11B-604.5.1 Side wall
grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with the front end positioned...
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
1630.4(d)
(d) Job assignments, job classifications, organizational structures, position descriptions, lines of progression, and seniority lists;...
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
§104.13(a)(1)
(1) The test score or other selection criterion, as used by the recipient, is shown to be job-related for the position in question, and...
-
§8.10(c)(4)
(4) Job assignments, job classifications, organizational structures, position descriptions, lines of progression, and seniority lists;...
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
§1630.4(a)(1)(iv)
(iv) Job assignments, job classifications, organizational structures, position descriptions, lines of progression, and seniority lists;...
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
Trail Slopes
Slopes are often described as a ratio of vertical distance to horizontal distance, or rise to run (figure 130)....
-
11B-216.4.1 Exit doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
Handrails
[ADA Stds. 4.9] Yes __ No __ N/A __ Comments: ___________________________________________ ...do the handrails extend horizontally at the top and bottom of each stair section to give...
-
4.4.3 Backrest and Armrest
strength of backs, armrests, and mounting devices shall comply with section 903.6 of the ABAAS, which states: “Allowable stresses shall not be exceeded for materials used when a vertical or horizontal...
-
Rotational Penetrometer
The test for stability requires the caster of the Rotational Penetrometer to be moved from side to side to determine the horizontal displacement of the surface material....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
1009.2.1 Elevators required
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal...
-
11B-216.4.1 Exit doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
1010.1.5 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
1009.2.1 Elevators required
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal...
-
1009.4.2 Area of refuge
Areas of refuge are not required for elevators accessed from a refuge area in conjunction with a horizontal exit....
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...