(2) A clear, sufficiently large, and sharply delineated picture of the interpreter's head and the participating individual's head, arms, hands, and fingers, regardless of his body position...
Search Results "Fixed Shower Head"
Commonly Searched Documents
-
§ 36.303(f)(2)
-
§ 35.160(d)(2)
(2) A clear, sufficiently large, and sharply delineated picture of the interpreter's head and the participating individual's head, arms, hands, and fingers, regardless of his body position...
-
11B-212.3 Sinks
A fixed bowl or basin with running water and drainpipe, as in a kitchen or laundry, for washing dishes, clothing, etc. (As differentiated from the definition of "Lavatory".). ...
-
§100.205(c)(3)(iii)
(iii) Reinforcements in bathroom walls to allow later installation of grab bars around the toilet, tub, shower, stall and shower seat, where such facilities are provided; and...
-
Toilet Rooms, Bathrooms, Bathing Facilities, and Shower Rooms [4.22 & 4.23]
[See subsections ...]
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND PALACE SPORTS AND ENTERTAINMENT, LLC, REGARDING THE PALACE OF AUBURN HILLS
[See subsections ...]
- Haws AXION® MSR Barrier-Free Recessed Eye/Face Wash
-
Toilet and Bathing Facilities: ADA Standard Section 807.2.4
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
- Whitehall Mfg. Hot & Cold Piezo Pushbuttons Electronic Valve Conical Faucet 4" Centerset
-
11B-607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
11B-607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
BATHROOM
[DSA-AC] For the purposes of Chapters 11A and 11B, a room which includes a water closet (toilet), a lavatory, and a bathtub and/or a shower....
-
11B-233.3.6 Graduate student and faculty housing at a place of education
with section 806.2.3 of the 2010 Standards. 2) Facilities with more than 50 beds covered by this part that provide common use bathing facilities shall provide at least one roll-in shower...
-
PLATFORM
A raised area within a building used for worship, the presentation of music, plays or other entertainment; the head table for special guests; the raised area for lecturers and speakers;...
-
One Unit Per Floor
One Unit Per Floor Where only one fixed unit is intended on a floor, dual access can be provided by: two separate units a combination "hi-lo" unit a fixed unit...
-
11B-607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
4.34.5.5(4) Controls
In the shower stall in Fig. 35(a), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
R309.5.1 Location
At accessible parallel parking spaces, parking meters shall be located at the head or foot of the parking space. Advisory R309.5.1 Location....
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
Bathtub Seats: ADA Standard Section 610.2
Section 610.2 covers the current ADA Standards for bathtub seats.
-
11B-610.2 Bathtub seats
Permanent seats at the head end of the bathtub shall be 15 inches (381 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub....
-
11B-607.4.2.1 Back wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....