The depth of wheelchair spaces shall comply with M303.2.3.
Search Results "Fixed Seat"
-
M303.2.3 Depth
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M303.2 Wheelchair spaces (Section-by-Section Analysis)
This is an introductory section.
-
EXHIBIT B
EXHIBIT B The average anthropometric dimensions employed shall be: (1) average eye height for a person sitting in a wheelchair is 47.45"; (2) horizontal distance from the eye of...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
§ 35.138(i) Purchasing multiple tickets
(i) Purchasing multiple tickets.
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
§ 35.138(d) Purchasing multiple tickets
(d) Purchasing multiple tickets.
- TOTO® MS854114EL Commercial Eco UltraMax One-Piece Toilet ADA Height
-
Study Objectives
Level, highest and lowest heights for transfers to i) a seat with no handhelds present, ii) a seat with grab-bars and iii) a seat with grab-bars and a backrest. b....
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from the...
- Whitehall Mfg. WH2142W2 Ligature-Resistant Toilet Wall Supply On-Floor Wall Waste
- Whitehall Mfg. Ligature Resistant Toilet Top Supply On-Floor
- Whitehall Mfg. WH2142T2 Ligature Resistant Toilet Top Supply On-Floor Wall Waste
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
These platforms cover groups of conventional seats and are used to provide groups of wheelchair seats and companion seats....
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
-
Location and Size
appropriate for the location and size of transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
- Delta Round Front Toilet C41901-WH
-
M303 Diagnostic Equipment Used by Patients in a Wheelchair (Section-by-Section Analysis)
M303 in the final rule establishes the technical requirements for diagnostic equipment used by patients seated in a wheelchair, such as weight scales with wheelchair spaces and mammography...
- American Standard Baby Devoro 1.28 gpf FloWise 10 Inch High Round Front Toilet
-
Accessible Sports Facilities
), sports fields (such as softball, football, lacrosse, baseball, and soccer) and other sports (such as gymnastics and wrestling) Dressing, fitting, and locker rooms Team or player seating...