Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
Search Results "Door Surface"
-
302.3 Openings
-
11B-904.3.3 Check writing surfaces
Where provided, check writing surfaces shall comply with Section 11B-902.3....
-
11B-904.3.3 Check writing surfaces
Where provided, check writing surfaces shall comply with Section 11B-902.3....
-
11B-904.3.3 Check writing surfaces
Where provided, check writing surfaces shall comply with Section 11B-902.3....
-
ADA Tolerances - Related Industry Standards
[See subsections ...]
-
ADA Tolerances Provisions
[See subsections ...]
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.2.3. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
-
Doorways: ADA Standard Section 405.7.5
Section 405.7.5 covers the current ADA Standards for doorway maneuvering clearance at ramp landings.
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Operator Mounting Bracket Variations Video
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
- LaCantina Doors
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
On diagnostic equipment used by patients in a seated position, M302.2.2 would require the size of the transfer surface to be 21 inches wide minimum and 15 inches deep minimum....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
H3
[ADA Standards § 4.13.9] Yes No If No, can the door be propped open without compromising privacy, or can the hardware be modified by adding new accessible hardware, or adapting...
-
Elevator Door Requirements [§407.3]
Elevator Door Requirements [§407.3]...
-
T503.4 Steps at Other Doorways
The walking surface on steps serving all other non-rail vehicle doorways shall be lighted at all times with 2 foot-candles (22 lux) minimum of illumination....