Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
Search Results "Display Unit"
Commonly Searched Documents
-
11B-809.10.7.5 Controls
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5.
- Willoughby Industries WRS-BF-FA-2HD Front Mounted Recessed Shower Panel 2 Fixed Shower Heads
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
- Access Board: Unobstructed Side Reach
- Access Board: Circular Space
- Access Board: Accessible Route Openings
- Access Board: Shower Seats
- Access Board: Maneuvering Clearance at Recessed Doors
- Access Board: International Symbol of TTY
- Access Board: How People with Low Vision or Blindness Approach Tactile Signs
-
206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
-
202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Americans with Disabilities Act or Section 504 of the Rehabilitation Act of...
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
7(1)(c)
(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that...
-
4.34.5.5 SHOWERS
If a shower is provided, it shall have the following features:
-
11B-216.8.1 Geometric symbols
Such spaces include but are not limited to; patient sleeping rooms, transient lodging guest rooms, and residential dwelling units....
-
413.1.1 Decoding and Display of Closed Captions
Players and displays shall decode closed caption data and support display of captions....
-
Best Practices for Accessible Prescription Drug Labeling Brochure
Best Practices for Accessible Prescription Drug Labeling Brochure: http://www.ncd.gov/sites/default/files/ADLP_508.pdf Pharmacies have a critical role to play to ensure the safety...
-
Fair Housing Act Design Manual
The manual was first published in August, 1996, and this update is intended to provide clear and helpful guidance about ways to design and construct housing which complies with the...
-
11B-216.8.1 Geometric symbols
Such spaces include but are not limited to; patient sleeping rooms, transient lodging guest rooms, and residential dwelling units. 2. ...
-
604.5 Grab Bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
Outdoor Rinsing Showers
If outdoor rinsing showers are provided in a recreation site, provide at least one hand-held shower spray unit with a hose 59 inches (1,500 millimeters) long minimum....