1) Where the Standard specifically refers to 303, such as 403.4 changes in level for walking surfaces: Here it is clear that changes in level that comply with either the ¼"...
Search Results "Court Floor Holding Cell"
Commonly Searched Documents
-
1) Where the Standard specifically refers to 303
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
- Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach – Drawing from the U.S. Access Board
- Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units – Drawing from the U.S. Access Board
- Figure 407.4.1(b) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(e) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(d) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(c) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach – Drawing from the U.S. Access Board
- Figure 407.4.1(a) Elevator Car Dimensions – Drawing from the U.S. Access Board
-
1(1)(b) Multiple entrances
Only one entrance is required to be accessible to any one ground floor of a building, except in cases where an individual dwelling unit has a separate exterior entrance, or where the building...
- Access Board: Clear Floor or Ground Space
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
Lavatories Adjacent to Partitions
Although we often times see accessories such as hand dryers or paper towel dispensers installed on the wall adjacent to the lavatory, the accessories cannot encroach into the clear floor...