Required receptacle outlets shall be permitted in floors when adjacent to sliding panels or walls....
Search Results "Building Permit"
Commonly Searched Documents
-
1136A.1 Receptacle heights
-
11B-202.3 Alterations
Although covered entities are permitted to limit the scope of an alteration to individual elements, the alteration of multiple elements within a room or space may provide a cost-effective...
-
Character Height: ADA Standard Section 703.2.5
EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be ½ inch (13 mm) minimum....
-
Clearance: ADA Standard Section 607.2
Section 607.2 covers the current ADA Standards for bathtub clearances.
-
11B-409.3.1 Power operation
Exception: In elevator cars with more than one opening, hoistway doors and gates shall be permitted to be of the manual-open, self-close type....
-
Is Identification of Which Means of Egress Are Available/Closest Necessary?
Once notified, people with a speech disability can use any standard means of egress from the building....
- DORMA BTS75V SERIES DOOR CLOSER
- Norton Surface Mounted 2800ST Cam Action Closer
-
MULTI-BEDROOM HOUSING UNIT
Multi-bedroom housing units are separate from one another and from common use spaces within a building....
-
F230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708....
-
230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708....
-
3104.2 Separate structures
Buildings connected by pedestrian walkways or tunnels shall be considered to be separate structures. Exceptions: 1. ... 2....
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-405.7.1 Slope
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
11B-405.7.1 Slope
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
405 Ramps
Alternate slope requirements are permitted for short ramps in existing facilities where space constraints effectively prohibit a 1:12 running slope....
-
STORY
[DSA-AC] That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
-
230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708....
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception....
- Otis Gen2 Elevator
-
Is Identification of Which Means of Egress Are Available/Closest Necessary?
Once notified, people who are deaf or hard of hearing can use any standard means of egress from the building....
-
§100.205(b)
building entrance....
-
11B-1007.2 Accessible routes
A slope not steeper than 1:4 for a 4 inch (102 mm) maximum rise shall be permitted. 4. ...
-
11B-1007.2 Accessible routes
A slope not steeper than 1:4 for a 4 inch (102 mm) maximum rise shall be permitted. 4....