[DSA-AC] An element specified by the regulations adopted by the Division of the State Architect-Access Compliance. Advisory Definition of ACCESSIBLE ELEMENT. ...
Search Results "BAR: Beach Access Route"
-
ACCESSIBLE ELEMENT
-
ACCESSIBLE ELEMENT
[DSA-AC] An element specified by the regulations adopted by the Division of the State Architect-Access Compliance. Advisory Definition of ACCESSIBLE ELEMENT. ...
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
-
F203.14 Raised Diving Boards and Diving Platforms
Raised diving boards and diving platforms shall not be required to comply with these requirements or to be on an accessible route....
-
203.14 Raised Diving Boards and Diving Platforms
Raised diving boards and diving platforms shall not be required to comply with these requirements or to be on an accessible route....
-
11B-206.2.4 Spaces and elements
At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility, including mezzanines, which...
-
11B-206.2.4 Spaces and elements
At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility, including mezzanines, which...
-
11B-206.2.4 Spaces and elements
At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility, including mezzanines, which...
-
A4.16.4 Grab Bars
Fig. A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet. Some wheelchair users can transfer from the front of the...
-
A4.16.4 GRAB BARS
Fig. A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet. Some wheelchair users can transfer from the front of the...
-
H21
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall 33 to 36...
-
F221.5 Lawn Seating
Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route....
-
11B-221.5 Lawn seating
Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route....
-
221.5 Lawn Seating
Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route....
-
11B-221.5 Lawn seating
Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route. ...
-
11B-221.5 Lawn seating
Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route....
-
68.101(c)(5)(B) Accessible route from parking area(s)
(B) An accessible route from the parking area(s) shall comply with TAS 206 and 402....
-
11B-206.2.9.2 Wheelchair spaces, ride seats designed for transfer, and transfer devices
spaces complying with Section 11B-1002.4, amusement ride seats designed for transfer complying with Section 11B-1002.5, and transfer devices complying with Section 11B-1002.6 shall be on an accessible...
-
11B-206.2.9.2 Wheelchair spaces, ride seats designed for transfer, and transfer devices
spaces complying with Section 11B-1002.4, amusement ride seats designed for transfer complying with Section 11B-1002.5, and transfer devices complying with Section 11B-1002.6 shall be on an accessible...
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches long minimum shall be installed on the head end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
R404.6 Approach
One full unobstructed side of a clear space shall adjoin a pedestrian access route or adjoin another clear space....