Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
Search Results "Water Closet Clear Floor Space"
-
804.6.4 Range or Cooktop
-
Outdoor Rinsing Showers [1011.2, 1011.3, and 1011.7]
At outdoor rinsing showers, a minimum of 60 by 60 inches of clear ground space must be provided....
-
Turning Space: ADA Standard Section 603.2.1
Section 603.2.1 covers the current ADA Standards for turning space in toilet and bathing rooms.
-
Turning Space: ADA Standard Section 612.3
Section 612.3 covers the current ADA Standards for turning space within saunas and steam rooms.
- Kohler Primary Elongated Toilet Bowl with Seat
-
Grab Bars [4.16.4]
It must be 36 inches long minimum, installed with one end space a maximum of 6 inches from the side wall....
-
CLEAR
[DSA-AC] Unobstructed.
-
CLEAR
[DSA-AC] Unobstructed.
-
Clear Width [1016.3]
The clear width of ORARs must be a minimum of 36 inches....
-
1011.2.1 Size and Location
The size of the clear ground space is based on the dimensions for maneuvering clearance at clear floor or ground spaces that are confined on all or part of three sides in 305.7 of the Architectural...
-
11B-604.5.1 Side wall
located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with the front end positioned 24 inches (610 mm) minimum in front of the water...
-
Re: American Standard AccessPRO Toilet
Production of the American Standard AccessPRO Toilet was discontinued, and the manufacturer says there is no replacement fixtures offered that provides ability to move laterally as...
-
Re: American Standard AccessPRO Toilet
Thanks for the heads up, Jonathan! We’ll be on the lookout for the Toto.
-
403.5.3 Passing Spaces
403.5.3 Passing Spaces. An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4....
-
A4.2.1(3) Space Requirements for Passing
(3) Space Requirements for Passing....
-
A4.2.1(3) Space Requirements for Passing
(3) Space Requirements for Passing....
- Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
Water Hydrants
Locate water spouts between 28 inches (710 millimeters) and 36 inches (915 millimeters) above the ground or floor surface on the edge of a clear space that is at least 72 inches (1,830 millimeters...