At least one of each type of element provided within picnic units with mobility features, including outdoor constructed features and parking spaces, must comply with the applicable technical...
Search Results "Single-Story Dwelling Unit (FHA)"
-
Elements Within Picnic Units With Mobility Features [F245.2.5]
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
F245.2.2 Picnic Facilities with More Than Two Picnic Units
Where picnic facilities contain more than two picnic units, at least 20 percent, but not less than two, of the picnic units shall provide mobility features complying with F245.2....
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work...
-
1133A.7, Item 1
1. The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided.
-
1133A.7, Item 1
1. The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided.
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space,...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
IV. Deeming 2010 Standards as an Alternative Accessibility Standard for Section 504 Compliance
entities that are subject to the requirements of title III of the ADA, 42 U.S.C. 12181–12189. 13 HUD’s scoping continues to apply regarding the required number of accessible residential dwelling...
-
3.3.3 Identification of Accessible Picnic Units
Where not all picnic units are accessible, the picnic units that are accessible shall not be identified by signs at the individual units....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
Elevator Exemption (Preamble, Section-by-Section Analysis)
Congress, however, chose not to require elevators in new small buildings, that is, those with less than three stories or less than 3,000 square feet per story....
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
Congress, however, chose not to require elevators in new small buildings, that is, those with less than three stories or less than 3,000 square feet per story....
-
4.20.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
4.20.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls. ...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls....
- Symmons Hand Shower T-600B-36-V
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
11B-233.3.1.2.5 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....