Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings....
Search Results "Perpendicular Parking Space"
Commonly Searched Documents
-
1011.2.4 Openings
-
Clear Floor Space
Clear floor spaces for inmates who use mobility devices...
-
11B-605.3 Clear floor space
11B-605.3 Clear floor space. A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
Side Entry: ADA Standard Section 1002.4.4.2
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
Wheelchair Space Overlap in Assembly Areas
Wheelchair Space Overlap in Assembly Areas....
-
Single-User Toilet Rooms: No Side Transfer Space
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel to the entrance to the camp shelter....
-
Water Closet Clear Floor Space
The proposed rule stated that no fixtures (other than the water closet) or obstructions were to be located within the clear floor space (604.3.1)....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. [2010 ADAS] Advisory 1008.4.2 Clear Floor or Ground Space....
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. Advisory 11B-1008.4.2 Clear floor or ground space....
-
11B-703.8.7 Character spacing
11B-703.8.7 Character spacing. Spacing shall be measured between the two closest points of adjacent low resolution VMS characters within a message, excluding word spaces....
-
11B-703.8.7 Character spacing
11B-703.8.7 Character spacing. Spacing shall be measured between the two closest points of adjacent low resolution VMS characters within a message, excluding word spaces....
-
1002.6.1 Clear Floor or Ground Space
1002.6.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
§ 36.304(f) Selling or serving space
(f) Selling or serving space....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.1 General
Clear floor or ground space shall comply with 305....
-
11B-703.8.7 Character spacing
Spacing shall be measured between the two closest points of adjacent low resolution VMS characters within a message, excluding word spaces....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...