Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. In accessible rooms or spaces, each glazed...
Search Results "Flush Control"
-
F229.1 General
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
Toilet Rooms North (Celebrity Spies)–Women [sic]: ff. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door...
-
§27.71(k)(4) Privacy.
(4) Privacy. Automated airport kiosks must provide the opportunity for the same degree of privacy of input and output available to all individuals. However, if an option is provided...
-
§ 27.71(k)(4) Privacy
(4) Privacy. Automated airport kiosks must provide the opportunity for the same degree of privacy of input and output available to all individuals. However, if an option is provided...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309 _|Operable Parts|_. Each glazed...
-
§ 38.123(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches. Doorways on the side wall shall have a minimum clear...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309. Each glazed opening required by...
-
229.1 General
229.1 General. Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required...
-
229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required by an...
-
Re: American Standard AccessPRO Toilet
Production of the American Standard AccessPRO Toilet was discontinued, and the manufacturer says there is no replacement fixtures offered that provides ability to move laterally as...
-
Re: American Standard AccessPRO Toilet
Thanks for the heads up, Jonathan! We’ll be on the lookout for the Toto.
-
Re: American Standard AccessPRO Toilet
That’s a tough situation since lateral adjustability is pretty rare in modern toilets. You might need to look into offset flanges or custom plumbing solutions. Finding that Toto...
-
11B-607.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
§27.71(k)(3)(iii) Status Indicators.
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
§ 27.71(k)(3)(iii) Status indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), must be discernible visually and by touch or sound; and...
-
11B-404.1 General
A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”....
-
11B-404.1 General
A sign visible from the approach side complying with Section 11B-703.5 shall be posted stating “Entry restricted and controlled by security personnel”....
- BEA Inc. Mount Boxes Bollards
- BEA Inc. High/Low Mount Boxes Bronze Bollards
- Deltrex Hand/Foot Push Plate Switches
- BEA Inc. Magic Switch Hardwired Touchless Sensor Door Opener MS21H (Wave to Open)
- Door King Inc. 1803 Telephone Entry System
-
Significant alternatives which minimize any significant economic impacts on small entities
Maximum cross slope of 2 percent required on pedestrian access routes, including within pedestrian street crossings with yield or stop control....
-
Exceptions for Specific Occupancies [§206.2.3]
Exceptions for Specific Occupancies [§206.2.3] The Standards also include limited exceptions for accessible routes between stories in air traffic control towers and, under certain...